Difference between revisions of "Microscopes"
Jump to navigation
Jump to search
Virus Epifluorescence
Line 104: | Line 104: | ||
|} | |} | ||
− | == Doxsey's | + | == Doxsey's Epifluorescence Microscope == |
{| | {| | ||
Line 111: | Line 111: | ||
|- | |- | ||
|Example Fluorophores | |Example Fluorophores | ||
− | |FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 650, Alexa 647, Cy5 | + | |Hoechst, DAPI, FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 650, Alexa 647, Cy5 |
|- | |- | ||
|Microscope | |Microscope | ||
Line 124: | Line 124: | ||
|Wide-field Camera | |Wide-field Camera | ||
|Digital CCD Hamamatsu Orca Flash 4, 2048x2048, 6.45um<sup>2</sup> pixels, '''16 bit''' (2 * 11 bit D/A merged), QE < 82% | |Digital CCD Hamamatsu Orca Flash 4, 2048x2048, 6.45um<sup>2</sup> pixels, '''16 bit''' (2 * 11 bit D/A merged), QE < 82% | ||
− | |||
− | |||
− | |||
|- | |- | ||
|Differential interference contrast (DIC) | |Differential interference contrast (DIC) | ||
Line 153: | Line 150: | ||
|} | |} | ||
− | == VESM == | + | == Virus Epifluorescence <s>Structured Light</s> Microscope (VESM) == |
{| | {| | ||
Line 205: | Line 202: | ||
|} | |} | ||
− | == TESM == | + | == TIRF EpiFluorescence Structured Light Microscope (TESM) == |
{| | {| |
Revision as of 19:12, 17 January 2017
Raffi's Spinning Disk Confocal Microscope
Types of Imaging | Real Time Live Cell 3D Imaging of fluorophores in modest to high quantity |
Example Fluorophores | Hoechst, DAPI, FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 633, Alexa 633, Cy5 |
Microscope | Nikon TE2000 |
Software | Metamorph |
Light Sources | Xeon Arc Lamp, Halogen Lamp, 4 Lasers (405nm, 488nm, 561nm, 636nm) |
Wide Field Camera | Photometrics CoolSNAP HQ, 1392x1040, 12 bits, 6.45um2 pixels, QE: 55-62% |
Spinning Disk Camera | QImaging Rolera-MGi, 512x512, 14 bits, 16um2 pixels, 30 fps, QE: up to 90% |
Nipkow Spinning Disk | Yokogawa CSU-10 |
Differential interference contrast (DIC) | Yes |
TIRF | No |
Structured Light | No |
Focus Stability | Yes (Perfect Focus by Nikon) |
XYZ Motorized Stage | Yes |
Nano Z Stage | No |
Piezo Z | No |
Microablation System | Yes |
Doxsey's Spinning Disk Confocal Microscope
Types of Imaging | Slower than Real Time 3D Imaging of fluorophores in modest to high quantity. |
Example Fluorophores | FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 650, Alexa 647, Cy5 |
Microscope | Zeiss |
Software | Metamorph |
Light Sources | Mercury Arc Lamp, Halogen Lamp, 3 Lasers (491nm, 561nm, 647nm) |
Wide-field Camera | None |
Spinning Disk Camera | Hamamatsu C4742-80, 1344x1024, 12 bits, 6.45um2 pixels, 8.8fps, QE : 60-72% |
Nipkow Spinning Disk | Yokogawa CSU-10 |
Differential interference contrast (DIC) | Unknown |
TIRF | No |
Structured Light | No |
Focus Stability | No |
XYZ Motorized Stage | Yes |
Nano Z Stage | No |
Piezo Z | Yes |
Microablation System | No |
Doxsey's Epifluorescence Microscope
Types of Imaging | Slower than Real Time 3D Imaging of fluorophores in modest to high quantity. |
Example Fluorophores | Hoechst, DAPI, FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 650, Alexa 647, Cy5 |
Microscope | Zeiss Axio Observer D1 |
Software | Metamorph |
Light Sources | X-Cite 120 (4 Color), Halogen Lamp |
Wide-field Camera | Digital CCD Hamamatsu Orca Flash 4, 2048x2048, 6.45um2 pixels, 16 bit (2 * 11 bit D/A merged), QE < 82% |
Differential interference contrast (DIC) | Yes |
TIRF | No |
Structured Light | No |
Focus Stability | No |
XYZ Motorized Stage | Yes |
Nano Z Stage | No |
Piezo Z | No |
Microablation System | No |
Virus Epifluorescence Structured Light Microscope (VESM)
Types of Imaging | Faster than Real Time Live Cell 3D Imaging of two fluorophores simultaneously in low to high quantity. |
Example Fluorophores | Hoechst, DAPI, FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 633, Alexa 632, Cy5 |
Microscope | Olympus ix81 |
Software | μManager |
Light Sources | Halogen Lamp, X-Cite LED 4 Color (395nm, 470nm, 550nm, 640nm) |
Camera 1 | Andor Zyla CMOS 4.2, 2048x2048, 12 & 16 bit modes, 6.45um2, 100fps, QE >70% |
Camera 2 | Andor Zyla CMOS 4.2, 2048x2048, 12 & 16 bit modes, 6.45um2, 100fps, QE >70% |
Differential interference contrast (DIC) | No |
TIRF | No |
Structured Light | No |
Focus Stability | Soon (pgFocus by Karl Bellvé) |
XYZ Motorized Stage | No |
Nano Z Stage | No |
Piezo Z | Yes |
Microablation System | No |
Notes | Housed in a Biosafety Level 2+ Room. Please see CDC Biosafety Level Criteria |
TIRF EpiFluorescence Structured Light Microscope (TESM)
Types of Imaging | Real Time Live Cell 3D Imaging of fluorophores in low to high quantity near or in the plasma membrane. |
Example Fluorophores | Hoechst, DAPI, FITC, DyLight 488, Alexa 488, GFP, DyLight 550, Alexa 555, RFP, Cy3, DyLight 650, Alexa 647, Cy5 |
Microscope | Olympus ix71 |
Software | μManager |
Light Sources | Halogen Lamp, Lasers (405nm, 491nm, 561nm, 660nm ) |
Camera | Andor iXon 885 Em, 1004x1002,14 bits, 8um2,30fps, QE > 65% |
Differential interference contrast (DIC) | No |
TIRF | Yes |
Structured Light | Yes |
Focus Stability | Yes (pgFocus by Karl Bellvé) |
XYZ Motorized Stage | No |
Nano Z Stage | No |
Piezo Z | Yes |
Microablation System | No |
Multi-Well Microscope
Types of Imaging | Slow Live Cell 3D Imaging of fluorophores in high quantity optionally using 96 well plates. |
Common Fluorophores | Hoechst, DAPI, FITC, GFP, RFP, Cy3, Cy5 |
Microscope | Zeiss Axio Observer Z1 |
Software | μManager |
Light Sources | Halogen Lamp, Xenon Arc Lamp |
Camera | Andor Clara, 1392x1040, 14 & 16 bit, 6.45um2, 11fps, QE 40-60% |
Differential interference contrast (DIC) | No |
TIRF | No |
Structured Light | No |
Focus Stability | Yes (Definite Focus by Zeiss) |
XYZ Motorized Stage | Yes |
Nano Z Stage | No |
Piezo Z | No |
Microablation System | No |